S J Standard Gate Valve Testing Method
S J Standard Gate Valve Testing Method
S J Standard Gate Valve Testing Method:
-
Open the gate plate.
-
Allow the internal pressure within the valve to rise to the specified test value.
-
Close the gate plate.
-
Immediately disassemble the gate valve and inspect both sides of the gate seal for leakage. If leakage is detected, promptly replace the valve with a new one.
Alternative Gate Valve Testing Methods
Medium Pressure Test:
As an alternative, inject the test medium into the plug on the valve cover until the specified pressure value is reached.
Inspect the sealing integrity on both sides of the gate plate. Note: This method is not suitable for gate valves with a nominal diameter smaller than DN32mm.
Blind Flange Test:
-
Open the gate plate.
-
Allow the system pressure inside the valve to reach the designated test value.
-
Close the gate plate.
-
Open one blind flange and inspect the sealing surfaces for leakage.
-
Repeat the test until compliance is achieved.
Additional Requirements:
The sealing performance tests for the packing gland and gasket of pneumatic gate valves shall be conducted prior to the valve sealing performance test.